Product 2/20


  • Item Code: M H52


Operating System                               : AC Potentiometer
Display Method                                  :
Resistance indication on meter with
                                                           linear scale galvanometer

Open Circuit Voltage                         : 50 V AC max e
Measurement Current                       : 15 mA AC max (using the 2-pole
                                                                 method: 3 mA AC max)

Measurement Frequency                    : 575 Hz (during setting to 2a or 3a)
                                                         600 Hz (during setting to 2b or 3b)
Operating Temperature &                 : 0 to 40°C (32°F to 104°F)

Humidity Range                                  : 80% RH or less (with no condensation)
                                                           Storage Temperature &                     : -10 to 50°C (14°F to 122°F)
                                                           Humidity Range                                    80% RH or less (with no condensation)

                                                           Usage Range                                       : Instrument is designed for earthing resistance
                                                                                                                         measurements in location up to a Height of
                                                                                                                         3,000 meters (except farms)
                                                            Power Supply                                   : Six R6P manganese batteries or six LR6
                                                                                                                         alkaline batteries
                                                                                                                         Rated supply voltage : 1.5 V x 6
                                                            Maximum Rated Power                 : 2.5 VA max

                                                            Accessories                                      : 9214 Auxiliary Earthing Rod

                                                                                                                       9215 Measuring Cable
                                                                                                                       (black 5m, yellow 10m, red 20m each one
                                                                                                                        9216 Cable Winder x 3 )
                                                                                                                        9393 Carrying Case
                                                                                                                       R6P manganese battery x 6
                                                                                                                       Instruction manual, Hand strap